Skip to product information
1 of 2

*Images shown are for illustration purposes and actual product may differ slightly*

Welch Allyn Diagnostic Cardiology Suite ECG

WELCCRXXWAXX

Each

Regular price
$2,375.00
Regular price
$2,375.00
Sale price
$2,375.00
Add Accessories - 4 Recommended
View Close
Welch Allyn 715006 ECG Clip
$115.50
3M Red Dot 2330 ECG Tab Electrodes
$18.02
3M Red Dot 2239 Micropore ECG Electrodes
$20.97
View More Close
1 review
Model

The Diagnostic Cardiology Suite Software is currently not validated for use on Windows 11. Please refer to the attached document for suitable Windows Platforms.

The Diagnostic Cardiology Suite Software will integrate only with Best Practice Premiere, it does not integrate with any other Practice Management Software.

    Models Available:

    • WAM - Wireless Acquisition Module
    • AM12 - Wired Acquisition Module
    • WAM & DICOM - Wireless Acquisition Module & DICOM communication
    • AM12 & DICOM - Wired Acquisition Module & DICOM communication


    Add Accessories - 4 Recommended
    View Close
    Welch Allyn 715006 ECG Clip
    $115.50
    3M Red Dot 2330 ECG Tab Electrodes
    $18.02
    3M Red Dot 2239 Micropore ECG Electrodes
    $20.97
    View More Close

    Feature

    • ECG and spirometry applications launched directly from EMR
    • Utilise one device for ECG and spirometry exams for a common workflow and setup
    • Capable of integration to ERM systems*
    • Wired acquisition with the Welch Allyn AM12 module
    • Wireless acquisition with the Welch Allyn WAM
    • Captures best 10 seconds of ECG data from memory, reducing need for repeat ECG's
    • Supports DICOM and HL7 communication
    • ECG complies with ACC, AHA and HRS recommendations for adult / paediatric patients
    • Streamlines workflow by capturing and saving an ECG is as few as two clicks
    • Save PDF's to any network folder
    • Defibrillator protection
    • VERITA ECG algorithm limits filtering to help show critical waveform data
    • Streamlines workflow by capturing and saving an ECG is as few as two clicks
    • Securely control user logins, assign user roles and access audit trails
    • 36 month warranty on the ECG device (UTK, WAM)
    • 13 month warranty on software
    • 90 day warranty on leads and clips
    • * Dependent upon EMR System, IT infrastructure and may require 3rd Party IT support to implement

    Specification

    • 12-lead resting ECG
    • Simultaneous acquisition of all 12 leads
    • Standard leads acquired: I, II, III, aVR, aVF, V1, V2, V3, V4, V5, V6
    • Frequency response: 0.05 Hz
    • 300 Hz
    • Defibrillator protection complies with AAMI standards and IEC 60601-2-25
    • QTc Method: Bazett, Fridericia, Linear
    • Extra Measurements: RR, QTcB, QTcF
    • Gain: 2.5, 5, 10, 20 mm/mV
    • Frequency response: 0.05-300 Hz
    • Digital sampling rate:
    • 40,000 samples/sec/channel used for pacemaker spike detection
    • 1,000 sample/sec/channel used for recording and analysis
    • Filters:
    • AC filter: None, 50 Hz, 60 Hz
    • Low-pass filter: 40 Hz, 150 Hz, 300 Hz
    • Report formats: Standard or Cabrera; 3+1, 3+3, 6, 6+6, or 12 channel