*Images shown are for illustration purposes and actual product may differ slightly*
Welch Allyn Diagnostic Cardiology Suite ECG
WELCCRXXWAXX
Each
- Regular price
- $2,375.00
- Regular price
-
$2,375.00 - Sale price
- $2,375.00
- Unit price
- per
Add Accessories - 4 Recommended
View
Close
Welch Allyn 715006 ECG Clip
$115.50
3M Red Dot 2330 ECG Tab Electrodes
$18.85
3M Red Dot 2239 Micropore ECG Electrodes
$21.95
View More Close
The Diagnostic Cardiology Suite Software will integrate only with Best Practice Premiere, it does not integrate with any other Practice Management Software.
Models Available:
- WAM - Wireless Acquisition Module
- AM12 - Wired Acquisition Module
- WAM & DICOM - Wireless Acquisition Module & DICOM communication
- AM12 & DICOM - Wired Acquisition Module & DICOM communication
Add Accessories - 4 Recommended
View
Close
Welch Allyn 715006 ECG Clip
$115.50
3M Red Dot 2330 ECG Tab Electrodes
$18.85
3M Red Dot 2239 Micropore ECG Electrodes
$21.95
View More Close
Couldn't load pickup availability


Feature
- ECG and spirometry applications launched directly from EMR
- Utilise one device for ECG and spirometry exams for a common workflow and setup
- Capable of integration to ERM systems*
- Wired acquisition with the Welch Allyn AM12 module
- Wireless acquisition with the Welch Allyn WAM
- Captures best 10 seconds of ECG data from memory, reducing need for repeat ECG's
- Supports DICOM and HL7 communication
- ECG complies with ACC, AHA and HRS recommendations for adult / paediatric patients
- Streamlines workflow by capturing and saving an ECG is as few as two clicks
- Save PDF's to any network folder
- Defibrillator protection
- VERITA ECG algorithm limits filtering to help show critical waveform data
- Streamlines workflow by capturing and saving an ECG is as few as two clicks
- Securely control user logins, assign user roles and access audit trails
- 36 month warranty on the ECG device (UTK, WAM)
- 13 month warranty on software
- 90 day warranty on leads and clips
- * Dependent upon EMR System, IT infrastructure and may require 3rd Party IT support to implement
Specification
- 12-lead resting ECG
- Simultaneous acquisition of all 12 leads
- Standard leads acquired: I, II, III, aVR, aVF, V1, V2, V3, V4, V5, V6
- Frequency response: 0.05 Hz
- 300 Hz
- Defibrillator protection complies with AAMI standards and IEC 60601-2-25
- QTc Method: Bazett, Fridericia, Linear
- Extra Measurements: RR, QTcB, QTcF
- Gain: 2.5, 5, 10, 20 mm/mV
- Frequency response: 0.05-300 Hz
- Digital sampling rate:
- 40,000 samples/sec/channel used for pacemaker spike detection
- 1,000 sample/sec/channel used for recording and analysis
- Filters:
- AC filter: None, 50 Hz, 60 Hz
- Low-pass filter: 40 Hz, 150 Hz, 300 Hz
- Report formats: Standard or Cabrera; 3+1, 3+3, 6, 6+6, or 12 channel